EVCO S.p.A. EVF 300 series | Installer manual ver. 1.1 | Code 144F300E114
Page 6 of 62
circuit breaker protection • •
electric absorption protection • •
Digital outputs: EVF318 EVF328
steam injection
8 A res. @ 250 VAC electro-
mechanical relay
8 A res. @ 250 VAC electro-
mechanical relay
steam generator
8 A res. @ 250 VAC electro-
mechanical relay
8 A res. @ 250 VAC electro-
mechanical relay
vent
8 A res. @ 250 VAC electro-
mechanical relay
8 A res. @ 250 VAC electro-
mechanical relay
extraction hood/multi-function output
16 A res. @ 250 VAC electro-
mechanical relay
16 A res. @ 250 VAC electro-
mechanical relay
technical compartment/switch-on/off fan
8 A res. @ 250 VAC electro-
mechanical relay
8 A res. @ 250 VAC electro-
mechanical relay
top
8 A res. @ 250 VAC electro-
mechanical relay
12 V, 30 mA solid state relay
floor
8 A res. @ 250 VAC electro-
mechanical relay
12 V, 30 mA solid state relay
chamber light
16 A res. @ 250 VAC electro-
mechanical relay
16 A res. @ 250 VAC electro-
mechanical relay
Communication ports: EVF318 EVF328
TTL type serial port • •
RS-48 serial port with MODBUS communication
protocol
• •
Other features: EVF318 EVF328
clock • •
signal buzzer and alarm • •
management of the power distributed at the top
and that distributed at the floor independently
from each other.
• •
management of the temperature of the top and
the floor independently from each other
• •